Skip to main content

Table 1 Statistical analysis of results of comparison of LAMP with PCR and blood smear examination using MedCalc's Diagnostic test evaluation calculator

From: An endpoint visualization loop-mediated isothermal amplification (LAMP) for detecting bubaline theileriosis

TEST

PCR

Blood smear

LAMP

Positive

Negative

Total

Positive

Negative

Total

Positive

23

4

27

16

11

27

Negative

0

73

73

0

73

73

Total

23

77

100

16

84

100

Statistics

Value

95% confidence interval

Value

95% confidence interval

Sensitivity

100.00%

85.18–100.00%

100.00%

79.41–100.00%

Specificity

94.81%

87.23–98.57%

86.90%

77.78–93.28%

Positive likelihood ratio

19.25

7.41–49.98

7.64

4.40–13.25

Negative likelihood ratio

0.00

 

0.00

 

Disease prevalence

23.00%

215.17–32.49%

16.00%

9.43–24.68%

Positive predictive value

85.19%

68.89–93.72%

59.26%

45.61–71.62%

Negative predictive value

100.00%

 

100.00%

 

Accuracy

96.00%

90.07–98.90%

89.00%

81.17–94.38%

Kappa

0.894

0.680

S.E. of kappa

0.052

0.086

95% confidence interval

0.792 to 0.995

0.511 to 0.849