Skip to main content

Table 3 Frequency response results—passive and FLC suspension system

From: Design of passive suspension system to mimic fuzzy logic control active suspension system

Type of system

First peak

Second peak

Amplitude (dB)

Frequency (Hz)

Amplitude (dB)

Frequency (Hz)

Passive system-initial

121.60

1.953

710.50

11.72

FLC active system-initial

92.01

1.953

495.70

11.72

Passive system-optimized

73.53

1.953

393.10

11.72

FLC active system-optimized

27.89

1.953

269.00

11.72