Skip to main content

Table 2 Full blood count profile using ex vivo approaches

From: Double-edged sword of biofouling potentials associated with haemocompatibility behaviour: titania nanotube arrays for medical implant surface technology

Full blood count

Average value (mg/dl)

Untreated

Ti

TNA

Total RBC

4.95 ± 0.78

4.95 ± 0.78

5.00 ± 0.71

Haemoglobin

142.00 ± 21.21

141.50 ± 21.92

142.00 ± 19.80

Haematocrit

0.44 ± 0.05

0.45 ± 0.07

0.46 ± 0.06

MCV

92.05 ± 1.61

90.91 ± 0.00

91.01 ± 0.14

MCH

28.71 ± 0.22

28.60 ± 0.06

28.40 ± 0.06

MCHC

311.90 ± 2.97

314.50 ± 0.71

312.10 ± 0.14

RDW

12.15 ± 0.49

12.15 ± 0.64

12.20 ± 0.57

Total WBC

5.73 ± 4.70

5.54 ± 4.52

5.94 ± 4.70

  1. Results indicate mean values ± SD from 3 different donors for the parameters of full blood count