Skip to main content

Table 1 Visual analogue scale scores (VAS) for laser and control groups during the study period

From: The evaluation of healing effect of low-level laser treatment following gingivectomy

Days

1

3

5

7

Test (mean ± SD)

4 ± 0.63

2.7 ± 0.64

1.9 ± 0.32

0.1 ± 0.3

Control (mean ± SD)

4.2 ± 0.41

4 ± 0.43

3 ± 0.43

0.5 ± 0.53

t value

t1 = − 0.80178

t3 = − 4.9

t5 = − 6.1

t7 = − 2.05

p value

0.211

0.0004*

0.0001*

0.027*

  1. A statistically significant reduction in VAS score in the laser compared to the control group at days 3, 5, and 7 p.s. Significant reduction in VAS score was shown between laser and control group at 3, 5, and 7 days post-operatively
  2. *Significant difference, p < 0.05